PSI-47
DAFT / DAFT-2
Dust and Aerosol Measurement Feasibility Test / Dust and Aerosol Measurement Feasibility Test-2
Checks that a modified P-Trak particle counter works in microgravity; the same instrument used in SAME was used to detect dust.
Relevance for a lunar base
27 / 100 · Low- Habitat atmosphere0.0
- Fuel realism7.5
- Fire-safety focus10.0
- Data richness4.0
- Modeling value5.0
Explainable score using the default weights; adjust them on the ranking page.
Test conditions
- Oxygen concentration
- 21%
- Total pressure
- 1.01 atm
- Airflow speed
- 5 – 20 cm/s
- Fuels
- dust and aerosols
- Fuel phase
- aerosol (dust)
- Sensors and measurements
- modified TSI P-Trak (isopropanol condensation and laser counting)
- Hardware
- Ground-based Dust/Aerosol Flammability Testing apparatus
Mitigates the risk of SAME by checking a modified P-Trak particle counter. ASSUMED: O2 21% and 1.013 atm are the ISS standard atmosphere, not stated in the PSI metadata for this investigation.
Findings
Space application
Telling smoke from dust reduces false alarms.
Application on Earth
A Shuttle-derived detector (Brunswick Incipient Fire Detector, 1978) already separated smoke from dust in mines.
Data available in PSI
33 public files, with an experimental table (CSV).
xls: 12 · pdf: 7 · txt: 6 · ppt: 3 · doc: 2 · zip: 1 · jpg: 1 · csv: 1
Publications
A Research Plan for Fire Prevention, Detection and Suppression in Crewed Exploration Systems
Ruff Gary, Urban David, King Merrill
doi:10.2514/6.2005-341 ↗Detection of Smoke from Microgravity Fires
Urban David, Griffin DeVon, Ruff Gary, Cleary Thomas, Yang Jiann, Mulholland George, Yuan Zeng-guang
doi:10.4271/2005-01-2930 ↗